Indirect waste receptor in epoxy coated cast iron with a large deep sump, 305 mm square grate and dome secondary strainer. Bottom outlet with inside gasket, 3 or 4 inch, 290 cm² free area. For restaurants, cafeterias, food markets and food processing plants.

MakeSaudicast
Model · Base SKUFD-5090-G · 5090G
Typeمصارف الأسطح والأرضيات والمناطق
Sizes3 inch / 75 mm – 6 inch / 160 mm
Size
SKU 104FD.5094G-old3 variants · Ready to quote
Dome TypeSecondary Strainer
Inside GasketOutlet Connection
290 cm²Strainer Free Area
3 inch / 75–6 inch / 160 mmSizes
Original ProductsVerified dealer, documented
توصيل موثوقفي جميع أنحاء المملكة العربية السعودية
48h RFQ ResponseTypical quotation target
18+ YearsPlumbing & drainage supply
PRODUCT OVERVIEW

Indirect Waste Receptor: Product Overview

The indirect waste receptor FD-5090-G from Saudi Cast is a deep sump cast iron drain made for kitchens and food areas. It has an epoxy coated cast iron large sump body, a square top grate, a secondary dome strainer inside the sump and a bottom outlet with an inside gasket connection. It receives waste water from food equipment, sinks and other fixtures that discharge through an open air gap, and carries it safely into the drainage system. Fanoos AlHadeeth Trading in Jeddah supplies the FD-5090-G as a Saudi Cast verified dealer. This page explains how the receptor works, where it is used, its sizes and specifications, and how to install and look after it. Indirect waste receptor FD-5090-G cast iron deep sump drain with square grateIn food buildings, many pieces of equipment are not allowed to connect straight to the drain pipe. Instead, their waste pipes end above a receptor, leaving an open gap. The receptor catches the water and passes it to the drainage system. This keeps dirty drain water from ever flowing back into food equipment. The FD-5090-G is built for this job. Saudi Cast describes it as a sanitary indirect waste receptor with a large sump body. The square grate sits level with the floor, and below it a dome-shaped secondary strainer protects the outlet. Key facts in short:
  • Model: Saudi Cast FD-5090-G (FD-5090 G series)
  • Body: epoxy coated cast iron, large sump
  • Top: square grate, 305 mm (Saudi Cast drawing)
  • Height: 215 mm (Saudi Cast drawing)
  • Secondary strainer: dome type
  • Outlet: bottom outlet, inside gasket connection
  • Outlet sizes: 3 inch / 75 mm and 4 inch / 110 mm (6 inch / 160 mm on request)
  • Strainer free area: 290 cm²

Key Features of the Indirect Waste Receptor

Large Sump BodyEpoxy coated cast iron with space for water from several pieces of equipment.
Square Grate305 mm square top, level with the floor; extra heavy duty.
Dome Secondary StrainerRounded shape reduces splashing and resists clogging.
High Flow290 cm² strainer free area.
Bottom OutletInside gasket connection, 3 inch / 75 mm or 4 inch / 110 mm.
Full DocumentsData sheet, drawing, compliance certificate and installation guide.

CI Area Drain FD-5090-G Specifications

Values confirmed for this product; anything not listed is available from our team on request.

SKU (selected)104FD.5094G-old
BrandSaudicast
ModelFD-5090-G
BrandSaudi Cast
TypeSanitary Indirect Waste Receptor, Deep Sump
BodyEpoxy Coated Cast Iron, Large Sump
GrateSquare, Extra Heavy Duty (material on request)
Secondary StrainerDome Type
Outlet TypeBottom Outlet
Outlet ConnectionInside Gasket
Outlet Sizes3 inch / 75 mm, 4 inch / 110 mm (6 inch / 160 mm on request)
Strainer Free Area290 cm²
Top Size305 mm Square
Overall Height215 mm
WeightOn request

Dimensions from the Saudi Cast FD-5090G drawing. Saudi Cast lists 3 and 4 inch outlets; confirm 6 inch availability with Fanoos.

Available Sizes and SKUs

3 variants
#SizeSKU Unit
1 3 inch / 75 mm 104FD.5093G-oldSELECTED EA
2 4 inch / 110 mm 104FD.5094G-oldSELECTED EA
3 6 inch / 160 mm 104FD.5096G-oldSELECTED EA

Why an Indirect Waste Receptor Matters in Food Areas

Kitchens, cafeterias and food factories produce a lot of waste water from dishwashers, ice machines, steam kettles, sinks and refrigerated cabinets. If this water backs up into equipment, food can be contaminated. An indirect connection with an air gap prevents this, and an indirect waste receptor is the fitting that makes it work at floor level. Saudi Cast states that the FD-5090-G is used in buildings where food is handled or processed, such as restaurants, cafeterias, food markets and food processing plants. The large sump gives the water space to slow down, and the dome strainer keeps food scraps and solids from entering the outlet pipe. Because one receptor can serve several nearby pieces of equipment, kitchen designers can group discharge pipes around a few well-placed receptors. This keeps the floor tidy, reduces the number of drain openings and makes daily cleaning simpler for kitchen staff. Important: the exact air gap and connection rules for food equipment are set by the project's plumbing design and the local authority. Follow them when you plan the pipe ends above the receptor.

How the FD-5090-G Works

  1. Waste pipes from food equipment end above the square grate, with an open air gap.
  2. Water falls through the grate into the large cast iron sump.
  3. Inside the sump, the dome secondary strainer covers the outlet.
  4. Water passes through the dome openings into the bottom outlet and the drainage pipe.
  5. Solids that pass the grate are held back by the dome, where they can be removed during cleaning.
Saudi Cast explains that the dome secondary strainer is preferred because its hemispherical shape greatly reduces splashing, and its large free area helps to prevent clogging and keeps the flow high.

FD-5090-G Sizes

Outlet size Outlet type Connection Note
3 inch / 75 mm Bottom outlet Inside gasket Size shown by Saudi Cast
4 inch / 110 mm Bottom outlet Inside gasket Size shown by Saudi Cast
6 inch / 160 mm Bottom outlet On request Please confirm availability with Fanoos

Indirect Waste Receptor Specifications

Specification Details
Model FD-5090-G
Brand Saudi Cast
Type Sanitary indirect waste receptor, deep sump
Body Epoxy coated cast iron, large sump
Grate Square, extra heavy duty (material on request)
Secondary strainer Dome type
Outlet type Bottom outlet
Outlet connection Inside gasket
Outlet sizes 3 inch / 75 mm, 4 inch / 110 mm (6 inch / 160 mm on request)
Strainer free area 290 cm²
Top size 305 mm square
Overall height 215 mm
Weight On request
Note: dimensions are taken from the Saudi Cast FD-5090G drawing. Check the latest data sheet before final design.

Indirect Waste Receptor or Funnel Drain?

Both products receive indirect waste, but they suit different situations:
  • FD-5090-G receptor: a large square sump at floor level. Good when several pipes discharge in one place, or when the floor around the equipment also needs draining.
  • Funnel floor drains (e.g. FD-5010F): a round funnel on a smaller drain, for one discharge pipe.
See our 5010F مصرف أرضي قمعي لتصريف المياه غير المباشرة page for the funnel type, or ask Fanoos which suits your kitchen layout.

How to Install the Indirect Waste Receptor

Safety: cast iron is heavy. Lift with two people and wear gloves and safety shoes.
  1. 1Check the drawings for the receptor position, finished floor level and outlet size.
  2. 2Plan the equipment pipes so each one ends above the grate with the required air gap.
  3. 3Prepare the slab opening. The body is 215 mm high on the Saudi Cast drawing.
  4. 4Connect the bottom outlet to the drain pipe through the inside gasket. Clean and lubricate the pipe end as the installation guide says.
  5. 5Set the grate level with the finished floor and support the body firmly.
  6. 6Pour concrete around the body. Keep concrete out of the sump and outlet.
  7. 7Fit the dome strainer and the square grate.
  8. 8Run water into the receptor and check the flow and the outlet joint.
Important: follow the Saudi Cast installation guide and local food hygiene and plumbing rules.

Cleaning and Maintenance

  • Lift the grate and remove food scraps and debris from the sump.
  • Take out and rinse the dome strainer, then put it back.
  • Wash the sump with hot water and a mild detergent.
  • Check that the outlet drains freely.
  • Check that equipment pipes still end above the grate with an open gap.
  • Refit the grate so it sits flat.
Caution: in kitchens, grease can build up in the sump and pipe. Clean the receptor often and make sure the building's grease management system is working. Warning: never remove the dome strainer during normal use. It stops solids from blocking the outlet.

Hygiene Tips for Food Areas

An indirect waste receptor in a kitchen needs more care than a drain in a corridor. Food waste can smell and attract insects if it stays in the sump.
  • Clean the indirect waste receptor at the end of every shift in busy kitchens.
  • Do not sweep food scraps into the grate.
  • Keep the area around the grate dry and free of boxes and equipment.
  • Include the receptors in the kitchen's cleaning schedule and checklist.

Planning the Indirect Waste Receptor Layout

  • Position: place the indirect waste receptor close to the equipment it serves, so discharge pipes are short and easy to clean.
  • Access: do not place equipment legs or bases on the grate.
  • Several pipes: the square top can take more than one discharge pipe if they are spaced correctly.
  • Floor slope: slope the floor towards the receptor if it also drains the floor.
  • Pipe route: the bottom outlet needs a pipe directly below the slab.

Saudi Cast Documents for the FD-5090-G

Saudi Cast publishes a document set for this indirect waste receptor. Fanoos can share these for consultant approvals:
  • FD-5090G data sheet
  • FD-5090G drawing
  • FD-5090G compliance certificate
  • FD-5090G installation guide
  • AutoCAD and 3D DXF files (from the Saudi Cast website)

Common Mistakes with Indirect Waste Receptors

  • Connecting equipment pipes directly into the indirect waste receptor with no air gap.
  • Setting the grate too high, so floor water cannot flow in.
  • Running the receptor without its dome strainer.
  • Placing equipment over the grate so it cannot be lifted for cleaning.
  • Letting grease build up because the sump is not cleaned often enough.

Benefits for Restaurant and Factory Owners

A well-chosen receptor makes daily kitchen work easier and protects the business.
  • Food safety: the air gap arrangement keeps drain water away from food equipment.
  • Less splashing: the dome strainer reduces splashing around the sump.
  • Fewer blockages: the large free area and dome help keep the outlet open.
  • Long life: the epoxy coated cast iron body is made for busy commercial floors.
  • Easy cleaning: the grate lifts off and the dome can be rinsed and refitted.
Many food-safety inspections look closely at floor drains. A clean, well-fitted receptor with the right air gaps helps a kitchen pass these checks.

Handling and Storage on Site

Keep the receptor in its packing until installation. Store it flat in a dry place and avoid dropping it, because cast iron can crack. Keep the grate, dome strainer and body together so no parts go missing. Protect the epoxy coating during handling. After installation, cover the grate during building work so cement, sand and tile adhesive do not fall into the sump or outlet.

Working with Kitchen Equipment Suppliers

Kitchen equipment is often chosen after the drainage is designed. Share the receptor positions with the kitchen equipment supplier early, so that every discharge pipe can be routed to the nearest receptor. When equipment changes, check that the pipes still end above a grate and are not extended into the sump. Fanoos can supply additional receptors if the final kitchen layout needs more drainage points.

Who Uses the FD-5090-G

  • MEP consultants: specify indirect waste receptors for kitchens and food plants.
  • Kitchen designers: plan receptor positions with the equipment layout.
  • Plumbing contractors: install receptors in hotels, malls and restaurants.
  • Facility managers: replace old or damaged receptors in food areas.

Signs a Receptor Needs Attention

  • Water overflows from the grate when equipment discharges.
  • Bad smells come from the sump.
  • The grate is cracked, loose or no longer flat.
  • The dome strainer is missing or damaged.
  • The epoxy coating or body is badly corroded.

Inspection Checklist

  • Is the grate in place and flat?
  • Is the dome strainer fitted?
  • Is the sump clean and free of grease?
  • Do equipment pipes end above the grate with an open gap?
  • Does water drain away quickly?
  • Is the area around the receptor dry and clean?

Choosing the Right Indirect Waste Receptor

  • Number of pipes: a large square receptor suits several discharge pipes.
  • Outlet size: 3 inch / 75 mm or 4 inch / 110 mm; ask Fanoos about 6 inch / 160 mm.
  • Outlet connection: inside gasket for push-fit pipe connection.
  • Traffic: confirm the grate rating for trolleys and loads in your kitchen.
  • Cleaning: place the indirect waste receptor where staff can reach it easily.

Ordering Checklist

  1. Model: FD-5090-G.
  2. Outlet size: 3 inch / 75 mm, 4 inch / 110 mm (or ask about 6 inch / 160 mm).
  3. Quantity.
  4. Project name and delivery location.
  5. Documents needed for approval.
  6. Your contact details for the quotation.

Why Buy the Indirect Waste Receptor from Fanoos

  • Saudi Cast verified dealer: original Saudi Cast drains.
  • 18+ years in plumbing and drainage: practical advice for kitchen and food-area drainage.
  • Stock in Jeddah: receptors, drains and fittings from one supplier.
  • Technical documents: Saudi Cast data sheets and drawings for your submittals.
  • Quick quotations: by phone or email.
Visit the Fanoos homepage for more drainage products, or see the Saudi Cast FD-5090G product page for the brand's own details.

Terms Explained

  • Indirect waste: waste water from equipment that discharges through an open gap instead of a direct pipe connection.
  • Receptor: the drain fitting that receives indirect waste.
  • Air gap: the open space between a pipe end and the receptor.
  • Sump: the deep part of the body where water collects.
  • Dome strainer: a rounded strainer that covers the outlet inside the sump.
  • Inside gasket outlet: an outlet with a rubber gasket inside that seals around the pipe.
  • Free area: the open area that water passes through.

Frequently Asked Questions

What is an indirect waste receptor?

It is a floor fitting that receives water from equipment pipes that end above it with an open gap. The FD-5090-G is a deep sump cast iron receptor for food areas.

Where is the FD-5090-G used?

Saudi Cast lists buildings where food is handled or processed, such as restaurants, cafeterias, food markets and food processing plants.

Why does it have a dome strainer?

The rounded dome reduces splashing, and its large free area helps prevent clogging and keeps the flow high.

Which outlet sizes are available?

Saudi Cast lists 3 inch and 4 inch outlets. Ask Fanoos about the 6 inch / 160 mm size.

What type of outlet connection does it have?

A bottom outlet with an inside gasket connection.

How big is the grate?

The square top is 305 mm on the Saudi Cast drawing.

How often should it be cleaned?

In busy kitchens, clean the indirect waste receptor daily. In lighter use, check it at least weekly.

Can you provide the data sheet?

Yes. Contact Fanoos for the Saudi Cast data sheet, drawing, compliance certificate and installation guide.

Can several equipment pipes discharge into one receptor?

Yes, the large square top can take more than one pipe if they are spaced correctly and each has its own air gap. Your plumbing design sets the final arrangement.

Can I order a spare grate or dome strainer?

Contact Fanoos with the model number and a photo of the existing indirect waste receptor, and we will check spare part availability.

What does it weigh?

The weight is available on request.

Order the Indirect Waste Receptor from Fanoos

Planning a kitchen, cafeteria or food factory? Fanoos AlHadeeth Trading in Jeddah supplies the Saudi Cast FD-5090-G indirect waste receptor. Call our sales team on 0546236905, email sales@fanoosksa.com, or use our contact page to request a quote today.

Related products

Need the CI Area Drain FD-5090-G for your project?

Send your SKUs, quantities and delivery location, or upload your BOQ.

CI Area Drain FD-5090-G enlarged view